Valve Drive by Linear Mover

Top  Previous  Next

**

With this kind of a drive an element is not controlled by the PLC directly, but indirectly by a linear mover that has to exist already.

On the edit mask you have to specify a maximum flow. This flow is varied from 0 to 100% dependent on the position of the linear mover. Length and orientation does not matter, the one end position of the linear mover is always 0% the other one is always 100%. You can use the linear mover with integrated sensors as well.

 

Up to now this drive is only available for the valve, the joint, the heating and more inadvertently for the pump.