Word Motor

Top  Previous  Next

**

This drive should only be used by teachers whose pupils use a version of TrySim smaller than V2.9.12. Professional users should use the new drive simple Frq converter that has got an enlarged functionality.

 

This drive corresponds to a frequency controlled drive or a proportional valve. It has to be connected to a word (E-, A-, M- or data-) of the PLC. Next to the address you have to specify as well at which value of the word the maximum speed shall be reached. If the word in the real PLC has to head for an analog output that shall specify a frequency converter +/- 10V you will have to enter 27648 here.

 

The word motor will also be used if none of the other drives seem to be appropriate, e.g. if you have a motor with 3 speeds. Then you have to program the heading for the speed yourself, best in OB3.

 

See also:

Other drives