Introduction |
General |
Structure of the system |
Machine |
System of coordinates |
Origin |
Editing the machine |
Start up |
Create new elements |
Marking elements |
Edit properties |
OK button |
Cancel button |
Fixing elements |
Edit window “Static element” |
Delete elements |
Select another view |
Color depth |
Resolution |
3-D view |
3-D control with keyboard |
3-D control with mouse |
Graphic filter |
Properties of the 3-D window |
Store/load a 3-D viewing angle |
Zoom |
Adress table |
Element tree |
Groups |
Group manager |
Group Editor |
Positioning elements |
Reference point |
Simulation of the machine |
How to find Elements |
Structuring huge Machines |
Common properties of elements |
General |
Name |
Father |
Child |
Position |
Size |
Fixabiltiy |
Visiblity |
Color |
PLC Connection |
Comment |
Anchor |
Script |
Static elements of simulation |
Overview |
Sensors |
Light barrier |
Light sensor |
Limit switch |
Limit Switch Nose |
Spy |
Distance Sensor |
Resolver for Transporter/Chain/Track |
Bar Code Scanner |
Running Wheel |
Actuators |
Generator |
Continuous generator |
Continuous dynamics / track |
Destroyer |
Linear mover |
Linear mover with sensors |
Conveyor |
Joint |
Hook |
Free point |
Chain |
Node |
Segment |
Turner |
Rider way |
Mangle |
Turntable |
Arc Belt |
Turnable Conveyor |
Controls |
Pushbutton |
LED |
Digital display |
Data Formats For Digital Display |
String display |
Slide controller |
Data formats for slide controller |
Text display |
Oscilloscope |
Multiple switch |
Master switch |
Contact-Editor of the master switch |
Fluids |
General |
Container |
Pipe |
Extended Pipe Properties |
Pump |
Valve |
Overpressure valve |
Check valve |
Flange |
Flow meter |
Level gauge |
Pressure sensor |
Analyzer |
Level switch |
Fluidor |
Misc. |
Saw |
Divider |
Cutter |
Melter |
Wedge |
Shifter |
Dynamic converter, straighter |
Press |
Automatic hook |
Sticker |
Pawl |
RFID antenna & data chip |
Box |
Board |
Bar |
Rider |
Reactor |
Peek |
List of peekable properties |
Poke |
List of pokeable properties |
Thermal elements |
Thermal mass |
Heating |
Characteristic curve |
Thermometer |
Thermostat |
Tools |
Background |
Stripe |
Cross |
Attractor |
Speed trigger |
Master List |
General information about turnable elements |
How to mark turnable elements |
Drives |
Simple frequency converter |
Valve drive by linear mover |
Joint drive by linear mover |
Heating drive by linear mover |
Servo drive for linear mover |
Servo drive for joint |
Direct adjustments at servo drive |
Word motor |
Word-drive for pump and valve |
Absolute real drive |
1 bit-drive for pump and valve |
Drives of the linear mover |
Bit motor for joint |
Bit drives of the joint |
Crank drive |
Analog value processing |
Dynamic elements of simulation |
Normal dynamics |
Turnable dynamics |
PLC |
Introduction |
Data memory |
General |
Naming inputs, outputs and memory bits |
Naming data in datablocks |
Instance data blocks |
CPU |
Introduction |
Accumulator 1 |
Accumulator 2 |
Accu 3 und 4 |
Result of logic operation (RLO) |
First Request |
Global data block register |
Instance data block register |
Adressregister 1 and 2 |
Status register |
Program |
Introduction |
Organzation blocks |
Functions |
Function blocks |
Static variables |
Temporary variables |
External (Soft) PLC |
General |
Safety guidelines |
Open interface of TrySim |
Interface, C-Code |
Interface, Pascal-Code |
Connection to external S7 via MPI-Datasnake |
SoftPLC not found |
SoftPLC not active yet |
Connection to external S7 via MPI (Prodave) |
PRODAVE MPI mini from Siemens |
Interface to SoftPLC of IBH softec |
Connection to external Allen-Bradley PLC |
Setting of I/O configuration |
Setting of a block of I/O configuration |
Setting of a block of I/O configuration for MPI |
Reference PLC |
Data types |
BOOL |
BYTE |
CHAR |
WORD |
INT |
DWORD |
DINT |
POINTER |
TIMER |
DATE |
DATE_AND_TIME |
TIME_OF_DAY |
ANY |
BLOCK_FB |
BLOCK_FC |
BLOCK_DB |
REAL |
STRING |
UDT |
Constants |
List of operations |
Bit-operations |
A |
A( |
AN |
AN( |
O |
O( |
ON |
ON( |
X |
X( |
XN |
XN( |
) (closing bracket) |
= (assignment) |
S |
R |
SET |
CLR |
NOT |
SAVE |
FP |
FN |
Operations with timers |
SD |
Switch on delay |
SF |
Switch off delay |
SP |
Pulse |
SE |
Extended Pulse |
SS |
Retentive on delay |
PV |
Output DU of a timer |
Output DE of a timer |
Insert Timers in FBD/LAD |
Specification of a timer |
Entering of duration while using timers |
Operations with counters |
Input PV of a counter |
Output CV of a counter |
Output BCD_V of the timer |
CU |
CD |
Set counter |
Reset counter |
FR |
Load and transfer operations |
L |
T |
LC |
Operations with integers |
+I |
-I |
*I |
/I |
MOD |
==I |
<>I |
>I |
>=I |
<I |
<=I |
NEGI |
+ (Plus) |
Operations with double integers |
+D |
-D |
*D |
/D |
MOD |
==D |
<>D |
>D |
>=D |
<D |
<=D |
NEGD |
+ (Plus) |
Operations with reals |
+R |
-R |
*R |
/R |
==R |
<>R |
>R |
>=R |
<R |
<=R |
ABS |
NEGR |
SQRT |
SQR |
LN |
EXP |
Jump operations |
Jump labels |
JU |
JCN |
JMZ |
JM |
JN |
JP |
JPZ |
JZ |
JNB |
JC |
JCB |
JBI |
JNBI |
Loop |
JL |
Not implemented jumps |
JO |
JUO |
JOS |
Shift and rotating operations |
SRD |
SSD |
RLD |
RLDA |
SLD |
SLW |
RRDA |
RRD |
SSI |
SRW |
Logical word and double word operations |
AD |
AW |
OW |
OD |
XOD |
XOW |
INVI |
INVD |
BCD operations |
BCD number |
ITB |
DTB |
BTD |
BTI |
Other conversions |
DTR |
ITD |
TRUNC |
RND |
RND+ |
RND- |
Trigonometric operations |
Radian angle |
SIN |
COS |
TAN |
ASIN |
ACOS |
ATAN |
Misc. operations with accu 1 |
TAK |
CAW |
CAD |
INC |
DEC |
+ (Plus) |
Operations with accu 3 and 4 |
PUSH |
POP |
LEAVE |
ENT |
Register indirect addressing |
Warning using AR1 or AR2 |
LAR1 or 2 |
+AR1 or 2 |
CAR1 or 2 |
CAR |
Indirect addressing with AR1 and AR2 |
Indirect addressing |
Operations for blocks |
OPN |
BEU |
BEC |
CALL |
CC |
UC |
CDB |
Nought / Zero operations |
NOP 0 or 1 |
BLD |
Master control relay (not implemented) |
Master control relay |
MCR( |
)MCR |
MCRA |
MRCD |
Differences between the TrySim-PLC to S7 |
Not implemented properties |
Master control relay |
Process interrupts |
Time of day interrupts |
Clock interrupt |
Limited ARRAYs |
Limited function of UDTs |
Function 'FR' with timers and counters |
JUO, JO and JOS |
STRING |
Variant implemented properties |
AND before OR |
Parameter-updating at functions |
Out-parameter of functions |
Data type check |
Program editor |
Block functions |
Create new blocks |
Block types |
Open and save blocks |
Delete a block |
Export and import blocks |
Edit OBs and FBs |
STL |
FBD |
LAD |
Transfer operand |
Fast operand-input by the numbers-block |
Operations on networks |
Editing of a block header |
Edit DBs |
Transfer a block into the PLC |
Watch the program execution |
Breakpoints and single step mode |
Set / delete a breakpoint in STL |
Set / delete a breakpoint in FBD/LAD |
Conditional breakpoints |
Specific features in FBD/LAD |
Rewire |
Cross reference list |
IEC-Functions |
SFB 3 (TP) Time as pulse |
SFB 4 (TON) On-Delay |
SFB 5 (TOF) Off-Delay |
FC 87 (LIFO) Read out the youngest value of a table |
FC 85 (FIFO) Read out the oldest value of a table |
FC 84 (ATT) Add a value to a FIFO/LIFO table |
Interface-panel |
Symbol table |
System function blocks and functions |
SFC 0 Set the CPU-Clock |
SFC 1 Read out the CPU-Clock |
SFC 20 Block move |
SFC 21 Fill |
SFC 22 Create DB |
SFC 23 Delete DB |
SFC 24 Information about DB |
SFC 64 Read out the system time in ms |
Export and Import |
Overview |
Export to Step®7 |
Export of the symbol table |
Problems with the export |
Import from Step®7 |
Import-filter |
Import of the symbol table |
Problems with the import |
Import from STEP®5 |
Import from STEP®5 Assignment lists |
Example session |
Example session |
Creating the machine |
Writing the PLC-program |
Starting the simulation |
Watch the program execution |
Possible errors in the example |
Menu items |
Project |
Project | New |
Project | Open |
Project | Open again |
Project | Save all |
Project | Save as |
Project | Add files |
Project | comment |
Project | Export |
Project | Import |
Project | Print |
Project | Exit |
Edit menu |
Edit | Edit |
Edit | Select all |
Edit | Select all children |
Edit | Reverse marking |
Edit | Fade Out |
Edit | Fade out children |
Edit | Fade in |
Edit | Fade in with children |
Edit | Focus |
Machine |
Machine | Start |
Machine | Stop |
Machine | Slower |
Machine | Faster |
Machine | Real time |
Machine | Extended |
Slow motion |
Quick motion |
Machine | Library |
Machine | Groups |
Machine | Media |
Media manager |
Machine | Dynamics | delete normals |
Machine | Reset time |
Graphic |
Graphic | Properties |
PLC |
PLC | Reset PLC |
PLC | Master reset |
PLC | Blocks in AS |
PLC | CPU |
PLC | CPU properties |
PLC | Clock memory |
PLC | Clock interrupt |
PLC | Retentive memory |
PLC | Cycle time monitoring |
PLC | Time system |
Block |
Block | Open |
Block | Open again |
Block | Save as |
Block | Print blocks |
Block | Block properties |
View |
View | Toolbar |
View | Status Bar |
View | Dimension |
View | Symbolic representation |
View | Rezoom |
View | Resize window |
View | Monitor (DB-window is active) |
Extras |
Extras | Quick Com/Script |
Extras | Quick Selected |
Window |
Window | Cascade |
Window | Next to each other |
Window | One below the other |
Help |
Options |
Overview |
Options | Simulation |
Options | Directories |
Options | Machine |
Options | Edit machine |
Options | PLC editor |
Options | Toolbars |
TrySim V2.9 © 2003 Cephalos GmbH